Sign In | Join Free | My himfr.com
Home > Boiler Manifold Headers >

Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel

Zhangjiagang HuaDong Boiler Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel from wholesalers
     
    Buy cheap Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel from wholesalers
    • Buy cheap Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel from wholesalers
    • Buy cheap Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel from wholesalers
    • Buy cheap Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel from wholesalers
    • Buy cheap Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel from wholesalers

    Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel

    Ask Lasest Price
    Brand Name : HDB
    Model Number : Boiler Manifold Header
    Certification : ISO9001 , SGS , TUV , ASME , EN
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 500 tons/month
    Delivery Time : 30 working days
    • Product Details
    • Company Profile

    Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel

    Boiler Fired Boiler Parts Headers For Power Plant 12Cr1MoVG Carbon Steel

    Details


    The pressures and temperatures that headers have to withstand depend on the component to which they are connected. A header connected to an economizer or to water wall panels is subject to less severe requirements on the material than a header connected to superheaters or reheaters.


    Depending on the temperature and pressure of headers, Vallourec supplies tubes in carbon steel to high-alloy ferritic steels such as T/P91 or T/P92, with sizes ranging from 88.9 mm to 406.4 mm.


    Features


    The pressures and temperatures that headers have to withstand depend on the component to which they are connected. A header connected to an economizer or to water wall panels is subject to less severe requirements on the material than a header connected to superheaters or reheaters.


    Depending on the temperature and pressure of headers, Vallourec supplies tubes in carbon steel to high-alloy ferritic steels such as T/P91 or T/P92, with sizes ranging from 88.9 mm to 406.4 mm.

    Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel
    Product Description
    The headers of boilers include water-cooling hinders of boilers proper, economizer hinders, superheater hinders, etc. They function for gathering, mixing and redistribution in boiler systems. In structure, they include end cover hinders or necking hinders.
    1Headers form an important part of all types of boilers.
    2Steam from the generating tubes is collected in headers which are therefore always under pressure.
    3This pressure may vary from 300 psi to 2000 psi. Since headers are always under pressure, the utmost care is taken by us while fabricating them.
    4Depending on the generating capacity of the boiler the header sizes fabricated by us vary from 100 mm to 600 mm NB. The stubs of various sizes are very carefully welded to the main body of the header to provide the desired openings from the header.

    Classification

    Enamelled Corrugated Sheet Baskets are a compact arrangement of profiled metal sheets placed in the Air Preheater rotor in two or more layers and plays the most important role in the process of heat recovery.
    The bottom layer, or the cold end layer, is where the air enters and the flue gases are discharged, and is therefore, subjected to severe corrosion due to acid dew point. The Material of Construction and the Profile design of the Heating Elements depends on the operating conditions, quality and type of fuel, etc.
    Parameters

    Diameter(OD)

    ¢76mm~¢914mm

    Diameter(OD)

    23000mm

    Temperature(℃)

    300~1500


    Boiler Fired Boiler Parts Power Plant Boiler Manifold Headers 12Cr1MoVG Carbon Steel


    Application

    Steam distribution headers are fabricated out of carbon steel or alloy steel seamless tubes. Customized or tailor made items are offered. Headers, after fabrication, are stress relieved to make the Steam distribution headers free from stresses. They are big pipe headers that transfer water from the downcomers to the risers through a combustion zone where the water gets partially heated to steam from the heat of fuel combustion.